Documents

2014 Led Lg 32lb56---T- Chassis Lb43b

Categories
Published
of 84
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Description
32lb56
Transcript
  Printed in KoreaP/NO : MFL67982505 (1401-REV00) CHASSIS : LB43B MODEL : 32LB56** 32LB56**-T* CAUTION BEFORE SERVICING THE CHASSIS,READ THE SAFETY PRECAUTIONS IN THIS MANUAL. LED TVSERVICE MANUAL North/Latin America http://aic.lgservice.comEurope/Africa http://eic.lgservice.com Asia/Oceania http://biz.lgservice.com Internal Use Only  - 2 - LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.Only for training and service purposes CONTENTS CONTENTS .............................................................................................. 2SAFETY PRECAUTIONS ........................................................................ 3SERVICING PRECAUTIONS ................................................................... 4SPECIFICATION ...................................................................................... 6ADJUSTMENT INSTRUCTION ............................................................... 8EXPLODED VIEW .................................................................................. 14SCHEMATIC CIRCUIT DIAGRAM ..............................................................  - 3 - LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.Only for training and service purposes Many electrical and mechanical parts in this chassis have special safety-related characteristics. These parts are identified by in the Schematic Diagram and Exploded View.It is essential that these special safety parts should be replaced with the same components as recommended in this manual to prevent Shock, Fire, or other Hazards. Do not modify the srcinal design without permission of manufacturer. General Guidance  An isolation Transformer should always be used  during the servicing of a receiver whose chassis is not isolated from the AC power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal injury from electrical shocks.It will also protect the receiver and it's components from being damaged by accidental shorts of the circuitry that may be inadvertently introduced during the service operation.If any fuse (or Fusible Resistor) in this TV receiver is blown, replace it with the specified.When replacing a high wattage resistor (Oxide Metal Film Resistor, over 1 W), keep the resistor 10 mm away from PCB.Keep wires away from high voltage or high temperature parts. Before returning the receiver to the customer,   always perform an AC leakage current check  on the exposed metallic parts of the cabinet, such as antennas, terminals, etc., to be sure the set is safe to operate without damage of electrical shock. Leakage Current Cold Check(Antenna Cold Check) With the instrument AC plug removed from AC source, connect an electrical jumper across the two AC plug prongs. Place the AC switch in the on position, connect one lead of ohm-meter to the AC plug prongs tied together and touch other ohm-meter lead in turn to each exposed metallic parts such as antenna terminals, phone  jacks, etc. If the exposed metallic part has a return path to the chassis, the measured resistance should be between 1 MΩ and 5.2 MΩ. When the exposed metal has no return path to the chassis the reading must be infinite. An other abnormality exists that must be corrected before the receiver is returned to the customer. Leakage Current Hot Check   (See below Figure) Plug the AC cord directly into the AC outlet. Do not use a line Isolation Transformer during this check.  Connect 1.5 K / 10 watt resistor in parallel with a 0.15 uF capacitor between a known good earth ground (Water Pipe, Conduit, etc.) and the exposed metallic parts.Measure the AC voltage across the resistor using AC voltmeter with 1000 ohms/volt or more sensitivity.Reverse plug the AC cord into the AC outlet and repeat AC voltage measurements for each exposed metallic part. Any voltage measured must not exceed 0.75 volt RMS which is corresponds to 0.5 mA.In case any measurement is out of the limits specified, there is possibility of shock hazard and the set must be checked and repaired before it is returned to the customer. Leakage Current Hot Check circuit IMPORTANT SAFETY NOTICE SAFETY PRECAUTIONS  - 4 - LGE Internal Use OnlyCopyright © LG Electronics. Inc. All rights reserved.Only for training and service purposes SERVICING PRECAUTIONS CAUTION: Before servicing receivers covered by this service manual and its supplements and addenda, read and follow the SAFETY PRECAUTIONS  on page 3 of this publication. NOTE  : If unforeseen circumstances create conict between the following servicing precautions and any of the safety precautions on page 3 of this publication, always follow the safety precau-tions. Remember: Safety First.General Servicing Precautions1. Always unplug the receiver AC power cord from the AC power source before;a. Removing or reinstalling any component, circuit board module or any other receiver assembly.b. Disconnecting or reconnecting any receiver electrical plug or other electrical connection.c. Connecting a test substitute in parallel with an electrolytic capacitor in the receiver. CAUTION : A wrong part substitution or incorrect polarity installation of electrolytic capacitors may result in an explo-sion hazard.2. Test high voltage only by measuring it with an appropriate high voltage meter or other voltage measuring device (DVM, FETVOM, etc) equipped with a suitable high voltage probe.Do not test high voltage by drawing an arc .3. Do not spray chemicals on or near this receiver or any of its assemblies.4. Unless specied otherwise in this service manual, clean electrical contacts only by applying the following mixture to the contacts with a pipe cleaner, cotton-tipped stick or comparable non-abrasive applicator; 10 % (by volume) Acetone and 90 % (by volume) isopropyl alcohol (90 % - 99 % strength) CAUTION : This is a ammable mixture.Unless specied otherwise in this service manual, lubrication of contacts in not required.5. Do not defeat any plug/socket B+ voltage interlocks with which receivers covered by this service manual might be equipped.6. Do not apply AC power to this instrument and/or any of its electrical assemblies unless all solid-state device heat sinks are correctly installed.7. Always connect the test receiver ground lead to the receiver chassis ground before connecting the test receiver positive lead. Always remove the test receiver ground lead last.8. Use with this receiver only the test xtures specied in this service manual. CAUTION : Do not connect the test xture ground strap to any heat sink in this receiver. Electrostatically Sensitive (ES) Devices Some semiconductor (solid-state) devices can be damaged eas-ily by static electricity. Such components commonly are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some eld-effect transistors and semiconductor “chip” components. The following techniques should be used to help reduce the incidence of component dam-age caused by static by static electricity.1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off any electrostatic charge on your body by touching a known earth ground. Alter-natively, obtain and wear a commercially available discharg-ing wrist strap device, which should be removed to prevent potential shock reasons prior to applying power to the unit under test.2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface such as aluminum foil, to prevent electrostatic charge buildup or expo-sure of the assembly.3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.4. Use only an anti-static type solder removal device. Some sol-der removal devices not classied as “anti-static” can generate electrical charges sufcient to damage ES devices.5. Do not use freon-propelled chemicals. These can generate electrical charges sufcient to damage ES devices.6. Do not remove a replacement ES device from its protective package until immediately before you are ready to install it. (Most replacement ES devices are packaged with leads elec-trically shorted together by conductive foam, aluminum foil or comparable conductive material).7. Immediately before removing the protective material from the leads of a replacement ES device, touch the protective mate-rial to the chassis or circuit assembly into which the device will be installed. CAUTION : Be sure no power is applied to the chassis or cir-cuit, and observe all other safety precautions.8. Minimize bodily motions when handling unpackaged replace-ment ES devices. (Otherwise harmless motion such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted oor can generate static electricity suf-cient to damage an ES device.)General Soldering Guidelines1. Use a grounded-tip, low-wattage soldering iron and appropri-ate tip size and shape that will maintain tip temperature within the range or 500 °F to 600 °F.2. Use an appropriate gauge of RMA resin-core solder composed of 60 parts tin/40 parts lead.3. Keep the soldering iron tip clean and well tinned.4. Thoroughly clean the surfaces to be soldered. Use a mall wire-bristle (0.5 inch, or 1.25 cm) brush with a metal handle.Do not use freon-propelled spray-on cleaners.5. Use the following unsoldering techniquea. Allow the soldering iron tip to reach normal temperature. (500 °F to 600 °F)b. Heat the component lead until the solder melts.c. Quickly draw the melted solder with an anti-static, suction-type solder removal device or with solder braid.CAUTION: Work quickly to avoid overheating the circuit board printed foil.6. Use the following soldering technique.a. Allow the soldering iron tip to reach a normal temperature (500 °F to 600 °F)b. First, hold the soldering iron tip and solder the strand against the component lead until the solder melts.c. Quickly move the soldering iron tip to the junction of the component lead and the printed circuit foil, and hold it there only until the solder ows onto and around both the compo-nent lead and the foil. CAUTION : Work quickly to avoid overheating the circuit board printed foil.d. Closely inspect the solder area and remove any excess or splashed solder with a small wire-bristle brush.
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks