Education

Compressor And Compressed Air Systems

Categories
Published
of 35
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Description
1. Training Session on Energy Equipment Compressors & Compressed Air Systems Presentation from the “ Energy Efficiency Guide for Industry in Asia”…
Transcript
  • 1. Training Session on Energy Equipment Compressors & Compressed Air Systems Presentation from the “ Energy Efficiency Guide for Industry in Asia” www.energyefficiencyasia.org © UNEP 2006 Electrical Equipment/ Compressors
  • 2. © UNEP 2006 Training Agenda: Compressor Electrical Equipment/ Compressors Introduction Types of compressors Assessment of compressors and compressed air systems Energy efficiency opportunities
  • 3. © UNEP 2006 <ul><li>Compressors: 5 to > 50,000 hp </li></ul><ul><li>70 – 90% of compressed air is lost </li></ul>Significant Inefficiencies Introduction Electrical Equipment/ Compressors (McKane and Medaris, 2003)
  • 4. © UNEP 2006 (eCompressedAir) <ul><li>Electricity savings: 20 – 50% </li></ul><ul><li>Maintenance reduced, downtime decreased, production increased and product quality improved </li></ul>Benefits of managed system Introduction Electrical Equipment/ Compressors
  • 5. © UNEP 2006 <ul><li>Intake air filters </li></ul><ul><li>Inter-stage coolers </li></ul><ul><li>After coolers </li></ul><ul><li>Air dryers </li></ul><ul><li>Moisture drain traps </li></ul><ul><li>Receivers </li></ul>Main Components in Compressed Air Systems Introduction Electrical Equipment/ Compressors
  • 6. © UNEP 2006 Training Agenda: Compressor Electrical Equipment/ Compressors Introduction Types of compressors Assessment of compressors and compressed air systems Energy efficiency opportunities
  • 7. © UNEP 2006 Two Basic Compressor Types Types of Compressors Electrical Equipment/ Compressors Type of compressor Positive displacement Dynamic Reciprocating Rotary Centrifugal Axial
  • 8. © UNEP 2006 (King, Julie) <ul><li>Used for air and refrigerant compression </li></ul><ul><li>Works like a bicycle pump: cylinder volume reduces while pressure increases, with pulsating output </li></ul><ul><li>Many configurations available </li></ul><ul><li>Single acting when using one side of the piston, and double acting when using both sides </li></ul>Reciprocating Compressor Types of Compressors Electrical Equipment/ Compressors
  • 9. © UNEP 2006 Screw compressor <ul><li>Rotors instead of pistons: continuous discharge </li></ul><ul><li>Benefits: low cost, compact, low weight, easy to maintain </li></ul><ul><li>Sizes between 30 – 200 hp </li></ul><ul><li>Types </li></ul><ul><ul><li>Lobe compressor </li></ul></ul><ul><ul><li>Screw compressor </li></ul></ul><ul><ul><li>Rotary vane / Slide vane </li></ul></ul>Rotary Compressor Types of Compressors Electrical Equipment/ Compressors
  • 10. © UNEP 2006 (King, Julie) <ul><li>Rotating impeller transfers energy to move air </li></ul><ul><li>Continuous duty </li></ul>Centrifugal Compressor Types of Compressors Electrical Equipment/ Compressors <ul><li>Designed oil free </li></ul><ul><li>High volume applications > 12,000 cfm </li></ul>
  • 11. © UNEP 2006 <ul><li>Efficiency at full, partial and no load </li></ul><ul><li>Noise level </li></ul><ul><li>Size </li></ul><ul><li>Oil carry-over </li></ul><ul><li>Vibration </li></ul><ul><li>Maintenance </li></ul><ul><li>Capacity </li></ul><ul><li>Pressure </li></ul>Comparison of Compressors Types of Compressors Electrical Equipment/ Compressors
  • 12. © UNEP 2006 Training Agenda: Compressor Electrical Equipment/ Compressors Introduction Types of compressors Assessment of compressors and compressed air systems Energy efficiency opportunities
  • 13. © UNEP 2006 <ul><li>Capacity: full rated volume of flow of compressed gas </li></ul><ul><li>Actual flow rate: free air delivery (FAD) </li></ul><ul><li>FAD reduced by ageing, poor maintenance, fouled heat exchanger and altitude </li></ul><ul><li>Energy loss: percentage deviation of FAD capacity </li></ul>Capacity of a Compressor Assessment of Compressors Electrical Equipment/ Compressors
  • 14. © UNEP 2006 <ul><li>Isolate compressor and receiver and close receiver outlet </li></ul><ul><li>Empty the receiver and the pipeline from water </li></ul><ul><li>Start the compressor and activate the stopwatch </li></ul><ul><li>Note time taken to attain the normal operational pressure P2 (in the receiver) from initial pressure P1 </li></ul><ul><li>Calculate the capacity FAD: </li></ul>Simple Capacity Assessment Method Assessment of Compressors Electrical Equipment/ Compressors P2 = Final pressure after filling (kg/cm2a) P1 = Initial pressure (kg/cm2a) after bleeding) P0 = Atmospheric pressure (kg/cm2a) V = Storage volume in m3 which includes receiver, after cooler and delivery piping T = Time take to build up pressure to P2 in minutes
  • 15. © UNEP 2006 Compressor Efficiency Assessment of Compressors Electrical Equipment/ Compressors <ul><li>Most practical: specific power consumption (kW / volume flow rate) </li></ul><ul><li>Other methods </li></ul><ul><ul><li>Isothermal </li></ul></ul><ul><ul><li>Volumetric </li></ul></ul><ul><ul><li>Adiabatic </li></ul></ul><ul><ul><li>Mechanical </li></ul></ul>
  • 16. © UNEP 2006 Isothermal efficiency P1 = Absolute intake pressure kg / cm2 Q1 = Free air delivered m3 / hr r = Pressure ratio P2/P1 Compressor Efficiency Assessment of Compressors Electrical Equipment/ Compressors Isothermal efficiency = Actual measured input power / Isothermal power Isothermal power (kW) = P1 x Q1 x loger / 36.7
  • 17. © UNEP 2006 Volumetric efficiency D = Cylinder bore, meter L = Cylinder stroke, meter S = Compressor speed rpm χ = 1 for single acting and 2 for double acting cylinders n = No. of cylinders Compressor Efficiency Assessment of Compressors Electrical Equipment/ Compressors Volumetric efficiency = Free air delivered m3/min / Compressor displacement Compressor displacement = Π x D2/4 x L x S x χ x n
  • 18. © UNEP 2006 <ul><li>Consequences </li></ul><ul><ul><li>Energy waste: 20 – 30% of output </li></ul></ul><ul><ul><li>Drop in system pressure </li></ul></ul><ul><ul><li>Shorter equipment life </li></ul></ul><ul><li>Common leakage areas </li></ul><ul><ul><li>Couplings, hoses, tubes, fittings </li></ul></ul><ul><ul><li>Pressure regulators </li></ul></ul><ul><ul><li>Open condensate traps, shut-off valves </li></ul></ul><ul><ul><li>Pipe joints, disconnects, thread sealants </li></ul></ul>Leaks Assessment of Compressors Electrical Equipment/ Compressors
  • 19. © UNEP 2006 <ul><li>Total leakage calculation: </li></ul><ul><li>T = on-load time (minutes) </li></ul><ul><li>t = off-load time (minutes) </li></ul><ul><li>Well maintained system: less than 10% leakages </li></ul>Leak Quantification Method Assessment of Compressors Electrical Equipment/ Compressors Leakage (%) = [(T x 100) / (T + t)]
  • 20. © UNEP 2006 <ul><li>Shut off compressed air operated equipments </li></ul><ul><li>Run compressor to charge the system to set pressure of operation </li></ul><ul><li>Note the time taken for “Load” and “Unload” cycles </li></ul><ul><li>Calculate quantity of leakage (previous slide) </li></ul><ul><li>If Q is actual free air supplied during trial (m3/min), then: </li></ul>Quantifying leaks on the shop floor Assessment of Compressors Electrical Equipment/ Compressors System leakage (m3/minute) = Q × T / (T + t)
  • 21. © UNEP 2006 <ul><li>Compressor capacity (m3/minute) = 35 </li></ul><ul><li>Cut in pressure, kg/cm2 = 6.8 </li></ul><ul><li>Cut out pressure, kg/cm2 = 7.5 </li></ul><ul><li>Load kW drawn = 188 kW </li></ul><ul><li>Unload kW drawn = 54 kW </li></ul><ul><li>Average ‘Load’ time =1.5 min </li></ul><ul><li>Average ‘Unload’ time = 10.5 min </li></ul>Example Assessment of Compressors Electrical Equipment/ Compressors Leakage = [(1.5)/(1.5+10.5)] x 35 = 4.375 m3/minute
  • 22. © UNEP 2006 Training Agenda: Compressor Electrical Equipment/ Compressors Introduction Types of compressors Assessment of compressors and compressed air systems Energy efficiency opportunities
  • 23. © UNEP 2006 <ul><li>Significant influence on energy use </li></ul>Energy Efficiency Opportunities Electrical Equipment/ Compressors 1. Location 2. Elevation <ul><li>Higher altitude = lower volumetric efficiency </li></ul>
  • 24. © UNEP 2006 3. Air Intake Electrical Equipment/ Compressors <ul><li>Keep intake air free from contaminants, dust or moist </li></ul><ul><li>Keep intake air temperature low </li></ul><ul><li>Every 4 o C rise in inlet air temperature = 1% higher energy consumption </li></ul><ul><li>Keep ambient temperature low when an intake air filter is located at the compressor </li></ul>Energy Efficiency Opportunities
  • 25. © UNEP 2006 4. Pressure Drops in Air Filter Electrical Equipment/ Compressors <ul><li>Install filter in cool location or draw air from cool location </li></ul><ul><li>Keep pressure drop across intake air filter to a minimum </li></ul><ul><ul><li>Every 250 mm WC pressure drop = 2% higher energy consumption </li></ul></ul>Energy Efficiency Opportunities
  • 26. © UNEP 2006 5. Use Inter and After Coolers Electrical Equipment/ Compressors <ul><li>Inlet air temperature rises at each stage of multi-stage machine </li></ul><ul><li>Inter coolers: heat exchangers that remove heat between stages </li></ul><ul><li>After coolers: reduce air temperature after final stage </li></ul><ul><li>Use water at lower temperature: reduce power </li></ul>Energy Efficiency Opportunities
  • 27. © UNEP 2006 Electrical Equipment/ Compressors <ul><li>Higher pressure </li></ul><ul><ul><li>More power by compressors </li></ul></ul><ul><ul><li>Lower volumetric efficiency </li></ul></ul><ul><li>Operating above operating pressures </li></ul><ul><ul><li>Waste of energy </li></ul></ul><ul><ul><li>Excessive wear </li></ul></ul>Energy Efficiency Opportunities 6. Pressure Settings
  • 28. © UNEP 2006 Electrical Equipment/ Compressors a. Reducing delivery pressure Operating a compressor at 120 PSIG instead of 100 PSIG: 10% less energy and reduced leakage rate Energy Efficiency Opportunities 6. Pressure Settings b. Compressor modulation by optimum pressure settings Applicable when different compressors connected c. Segregating high/low pressure requirements Pressure reducing valves no longer needed
  • 29. © UNEP 2006 Electrical Equipment/ Compressors d. Design for minimum pressure drop in the distribution line <ul><li>Pressure drop: reduction in air pressure from the compressor discharge to the point of use </li></ul><ul><li>Pressure drop < 10% </li></ul><ul><li>Pressure drops caused by </li></ul><ul><ul><li>corrosion </li></ul></ul><ul><ul><li>inadequate sized piping, couplings hoses </li></ul></ul><ul><ul><li>choked filter elements </li></ul></ul>Energy Efficiency Opportunities 6. Pressure Settings
  • 30. © UNEP 2006 Electrical Equipment/ Compressors d. Design for minimum pressure drop in the distribution line Energy Efficiency Opportunities 6. Pressure Settings Typical pressure drop in compressed air line for different pipe size (Confederation of Indian Industries)
  • 31. © UNEP 2006 7. Minimizing Leakage Electrical Equipment/ Compressors <ul><li>Use ultrasonic acoustic detector </li></ul><ul><li>Tighten joints and connections </li></ul><ul><li>Replace faulty equipment </li></ul>8. Condensate Removal <ul><li>Condensate formed as after-cooler reduces discharge air temperature </li></ul><ul><li>Install condensate separator trap to remove condensate </li></ul>Energy Efficiency Opportunities
  • 32. © UNEP 2006 9. Controlled usage Electrical Equipment/ Compressors <ul><li>Do not use for low-pressure applications: agitation, combustion air, pneumatic conveying </li></ul><ul><li>Use blowers instead </li></ul>10. Compressor controls <ul><li>Automatically turns off compressor when not needed </li></ul>Energy Efficiency Opportunities
  • 33. © UNEP 2006 9. Maintenance Practices Electrical Equipment/ Compressors <ul><ul><li>Lubrication: Checked regularly </li></ul></ul><ul><ul><li>Air filters: Replaced regularly </li></ul></ul><ul><ul><li>Condensate traps: Ensure drainage </li></ul></ul><ul><ul><li>Air dryers: Inspect and replace filters </li></ul></ul>Energy Efficiency Opportunities
  • 34. Training Session on Energy Equipment Compressors & Compressed Air Systems THANK YOU FOR YOUR ATTENTION © UNEP GERIAP Electrical Equipment/ Compressors
  • 35. Electrical Equipment/ Compressors © UNEP 2006 Disclaimer and References <ul><li>This PowerPoint training session was prepared as part of the project “Greenhouse Gas Emission Reduction from Industry in Asia and the Pacific” (GERIAP). While reasonable efforts have been made to ensure that the contents of this publication are factually correct and properly referenced, UNEP does not accept responsibility for the accuracy or completeness of the contents, and shall not be liable for any loss or damage that may be occasioned directly or indirectly through the use of, or reliance on, the contents of this publication. © UNEP, 2006. </li></ul><ul><li>The GERIAP project was funded by the Swedish International Development Cooperation Agency (Sida) </li></ul><ul><li>Full references are included in the textbook chapter that is available on www.energyefficiencyasia.org </li></ul>
  • We Need Your Support
    Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

    Thanks to everyone for your continued support.