Copyright © 2005 ComAp s.r.o. Written by Ladislav Kadanik Prague, Czech Republic ComAp, spol. s r.o. Světova 7, 180 00 Praha 8, Czech Republic Tel: +420 2 66316661, Fax: +420 2 66316647 E-mail: info@comap.cz, www.comap.cz Troubleshooting guide Compact Controller for Stand-by and Parallel Operating Gen-sets InteliGen ® InteliSys ® Software version IG-6
Transcript
   Copyright © 2005 ComAp s.r.o. Written by Ladislav Kadanik Prague, Czech Republic ComAp, spol. s r.o. Sv ě tova 7, 180 00 Praha 8, Czech Republic Tel: +420 2 66316661, Fax: +420 2 66316647 E-mail: info@comap.cz, www.comap.cz Troubleshooting guide Compact Controller for Stand-by and Parallel Operating Gen-sets InteliGen ®  InteliSys ®   Software version IG-6.2, IS-3.4, August 2005    Troubleshooting Guide, ©ComAp – August 2005 - 2 - IG-6.2-IS-3.4- Troubleshooting Guide.pdf Table of Contents Table of Contents..........................................................................................................................................- 2 -   Troubles.........................................................................................................................................................- 5 -   Interference and over voltage transient protections..................................................................................- 5 -   Power supply input could be damaged, if ............................................................................................- 5 -   Binary Output could be overloaded , if ................................................................................................- 5 -   Binary Input could be burned, if ...........................................................................................................- 5 -    Analogue Output could be overloaded, if ............................................................................................- 5 -    Analogue Input could be disturbed, if ..................................................................................................- 5 -   RPM Input could be disturbed, if ..........................................................................................................- 5 -   Load sharing line is not working ..........................................................................................................- 5 -   CAN-Bus line is not working ................................................................................................................- 6 -   General......................................................................................................................................................- 6 -   IG controller works but displays fix “strange code”...............................................................................- 6 -   Often IG display refreshing...................................................................................................................- 6 -   The controller display is dark................................................................................................................- 6 -   Supply is OK, display is still dark..........................................................................................................- 6 -   IG screens returns to the Main measure screen..................................................................................- 6 -   Controller works properly but display is empty.....................................................................................- 6 -   IS screen is dark...................................................................................................................................- 6 -   Unexpected behavior after firmware upgrade......................................................................................- 6 -   Controller remains in the “Init” state......................................................................................................- 6 -   How to check the configuration of IG....................................................................................................- 6 -   How to check the configuration of IS....................................................................................................- 6 -   Controller Mode cannot be changed from OFF....................................................................................- 7 -   Controller mode changes itself.............................................................................................................- 7 -   Controller doesn't stop the engine on any alarm although it reports it in the Alarm list........................- 7 -   No response on Start/Stop keys...........................................................................................................- 7 -   Controller is in the Not ready state and Alarm list is empty...............................................................- 7 -   MCB fail is reported although the MCB feedback is OK.......................................................................- 7 -   Controller does not close GCB in MAN or AUT mode..........................................................................- 7 -   Some setpoints cannot be changed.....................................................................................................- 7 -   No Time stamp history record is written in the IG history..................................................................- 7 -   IG front panel red LED on the gen-set side lights or blinks..................................................................- 7 -   When power cut comes, gen-set does not start...................................................................................- 7 -   I have lost the IG Password and/or Access code.................................................................................- 7 -   It is not possible to remove catches to take controller out from switchboard.......................................- 8 -   RPM measuring.........................................................................................................................................- 8 -   Pickup signal.........................................................................................................................................- 8 -   RPM measuring....................................................................................................................................- 8 -   Controller detects RPM on no running gen-set....................................................................................- 8 -    Analog measuring.....................................................................................................................................- 8 -   IG does not measure analog value.......................................................................................................- 8 -   Why the Pt100 sensor cannot be used.................................................................................................- 8 -    Any of analog inputs does not measure correctly.................................................................................- 8 -   Sensor failure is detected.....................................................................................................................- 8 -    Analogue input value is XXXX..............................................................................................................- 8 -   Current output sensor influences resistor sensor measuring...............................................................- 8 -   Controller measures wrong values from current output sensor............................................................- 8 -   Power measuring......................................................................................................................................- 9 -    Active and reactive power measurement shows unlikely values..........................................................- 9 -   Wrong mains or bus voltage and frequency measuring.......................................................................- 9 -   Controller does not measure generator current....................................................................................- 9 -   Maximal current of the analog output on IG-IOM cannot reach 20 mA................................................- 9 -   I cannot find a neutral current measurement in SPtM..........................................................................- 9 -   Generator overcurrent protection does not react..................................................................................- 9 -   IG Starter kit..............................................................................................................................................- 9 -      Troubleshooting Guide, ©ComAp – August 2005 - 3 - IG-6.2-IS-3.4- Troubleshooting Guide.pdf  After MCB closes MCB fail is detected.................................................................................................- 9 -    Although maximal current is adjust by pot, IG displays low power value.............................................- 9 -   Multiple gen-set applications.....................................................................................................................- 9 -   Temporary generator voltage increasing or decreasing.......................................................................- 9 -   The IG and/or IS and /or InteliMains are reset continuously................................................................- 9 -   What is the sequence of GCB closing when more engines starts at once to the dead bus...............- 10 -   The system reserve does not correspond to the number of running engines....................................- 10 -   Power and PF sharing does not operate well.....................................................................................- 10 -   Two or more engines starts and stops at the same time....................................................................- 10 -   Setpoint replication does not work......................................................................................................- 10 -   Binary outputs SYSTEM READY and SYSTEM RES OK do not operate..........................................- 10 -   How to check proper CAN bus connection.........................................................................................- 10 -   How to check actual IG-MU sw version..............................................................................................- 10 -   CAN bus connection problems...........................................................................................................- 10 -   Sync/load control.....................................................................................................................................- 10 -   IG-PC(LS)M does not operate properly..............................................................................................- 10 -   InteliSys Sync/Load control does not operate....................................................................................- 10 -   Speed regulation does not hold the speed on the nominal speed level.............................................- 10 -   IG-PC(LS)M speed governor output is at the end position –10V or 10V not only during the transients (SPtM or MINT only)...........................................................................................................................- 11 -   Synchronizing operates well (synchroscope indicates proper slip and angle), but GCB (or MCB) does not close..............................................................................................................................................- 11 -   InteliMains doesn't start synchronizing after MCB is pressed............................................................- 11 -   Volt/PF control.........................................................................................................................................- 11 -   IG-AVRi connection............................................................................................................................- 11 -   Voltage regulation does not hold the voltage on the nominal voltage level........................................- 11 -   Voltage regulation is at 0% position (MINT).......................................................................................- 11 -    AVR output is at the end position 0 or 100 % not only during the transients (SPtM or MINT only)...- 11 -   PF or PFS control does not operate well............................................................................................- 11 -   Controller setting and configuration........................................................................................................- 11 -   IS configuration import........................................................................................................................- 11 -   What means InteliSys message SD BINx, SD BOUTx, SD AINx.......................................................- 12 -   It is not possible to change setpoint....................................................................................................- 12 -   Not enough memory for InteliSys external modules configuration.....................................................- 12 -   Some set points groups have a yellow background...........................................................................- 12 -   How find out the setpoints limits.........................................................................................................- 12 -   It is not possible to configure IS Programmable functions..................................................................- 12 -   Controller malfunction after a new application download...................................................................- 12 -   WinEdit – MultiEdit..................................................................................................................................- 12 -   Before the first direct connection........................................................................................................- 12 -   Communication via RS232 does not work..........................................................................................- 13 -   Controller looks dead after interruption during reprogramming..........................................................- 13 -   Unsuccessful IS programming............................................................................................................- 13 -   History stops recording.......................................................................................................................- 13 -   Unsuccessful programming message.................................................................................................- 13 -   How to open default archive in OFF line connection..........................................................................- 13 -   How to change PC COM port before opening connection.................................................................- 13 -   How to open default archive in ON line connection............................................................................- 13 -   I can’t open communication to gensets group....................................................................................- 13 -   When WinEdit is started from MultiEdit with entered password, the password symbol is gray and no protected functions are enabled.........................................................................................................- 14 -   In WinEdit - Open connection window there are no sites visible........................................................- 14 -   WinEdit History in on-line connection does not correspond to the history in controller......................- 14 -   The display shows: Configuration table error.....................................................................................- 14 -   DDE server messages............................................................................................................................- 14 -   Timeout (continuous).........................................................................................................................- 14 -   Timeout (sometimes).........................................................................................................................- 14 -   TAPI: requested modem (#) not found...............................................................................................- 14 -   TAPI: unavailable modem...................................................................................................................- 14 -   TAPI: Line unexpectedly closed.........................................................................................................- 14 -   TAPI: Can’t create connection............................................................................................................- 14 -   Connected Modem does not operate.................................................................................................- 15 -      Troubleshooting Guide, ©ComAp – August 2005 - 4 - IG-6.2-IS-3.4- Troubleshooting Guide.pdf Connected Terminal does not operate...............................................................................................- 15 -   Wrong Access code............................................................................................................................- 15 -   Multiple IG controllers connection.......................................................................................................- 15 -   NV RAM error.....................................................................................................................................- 15 -   It is not possible to open Active call connection.................................................................................- 15 -   GSM Modem connection – SMS.............................................................................................................- 15 -   It is not possible to get any connection (data, SMS) with controller through GSM modem...............- 15 -   How to set the telephone number and the Gen-set name..................................................................- 15 -   GSM modem connected, warning call (shut down, slow down...) enabled, Act calls enabled, SMS enabled. SMS function properly, but modem data call (to WE) is not performed.............................- 16 -   Controller does not respond to SMS messages.................................................................................- 16 -  
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks