  T5000 Paralleling Relay ã Check synchronizer for enabling closure of circuit breakersã Specially designed for automatic closing of fast circuit breakersã Visual indication of voltage and closing signalã Output signal minimum 0.5 seconds duration for automatic closureã Cost effective and highly reliable compact designã 50 hours burn-in before final test ã Operating temperature range: -20°C to +70°Cã Certified by major classification societiesã Flame retardant enclosureã Screw or DIN rail mounting Application The T5000 Paralleling Relay can be used as a check synchronizer, inhibiting closure of circuit breaker if synchroni-zing parameters such as voltage, frequency and phase angle are outside limits, thus preventing generator damage and disturbance to the busbar.The T5000 can also be used as synchro-nizing aid for manual or automatic synchronization where voltage and frequency are adjusted by the operator to roughly the values required, and the unit will provide a closing signal to the circuit breaker at phase accordance.The T5000 is a part of the SELCO T-Line series with modular units for protection, control and monitoring of generators,  both in marine and land-based applica-tions. The T5000 is type approved by major marine classification societies. Function A built-in relay will close when voltage, frequency and phase are within limits. The relay output can be connected in series with a manually operated contact to operate the circuit breaker between the 2 systems, e.g. a generator to a  busbar. A D  voltage adjustment ( D U, scale 10-15%)  is provided on the front of the unit for combined adjustments of limits for voltage difference, frequency difference and phase difference. These limits are internally related to obtain optimal and safe operational performance.With the scale adjusted to the minimum position, the voltage difference ( D U) is ±10%. This corresponds to a phase difference ( Df ) of ±6° and a frequency difference ( D F) of ±0.15Hz. These numbers  are internally inverse related in such a way that a larger voltage difference ( D U), will allow only reduced phase difference ( Df )   and frequency difference  ( D F ). With the scale adjusted to the maximum position, the voltage difference ( D U) is ±15%. This corresponds to a phase difference ( Df ) of ±9° and a frequency difference ( D F) of ±0.225Hz. As above, these numbers are internally inverse related.A red LED marked “RELAY” on the front of the unit indicates that the output relay is activated.The output relay is activated all the time during phase accordance. However, the T5000 will always give an output pulse with a minimum duration of 0.5 seconds, meaning there will be enough time for the circuit breaker to close. CLOSINGSIGNAL AUTOMATIC CLOSURE         T        5         0         0         0  1992010765231L1L2L3 Automatic closure In order to use the T5000 with automatic closure ,terminals 19 and 20 should be interconnected, and the T5000 will now operate as illustrated in fig. 2.This figure shows the closing phase difference ( Df ) as a function of frequency difference ( D F), assuming that there is no voltage difference present and that the D  voltage setting is ±10%.For a very small D F it is seen that the D f  is 6°. For higher values of D F, the D f  will vary as shown.The line I shows the closing signal directly from the T5000.The line II shows the main contact closure with an additional circuit breaker operation time of 50 msec.At a low D F, the phase difference will change very slowly and the additional 50 msec. have almost no effect on the difference between the two curves. At a higher D F, the phase difference will change faster, and thus the difference between the two curves becomes larger.However, the curves also show that the phase difference at breaker closure will not exceed ± 6°,  provided the circuit breaker is a fast operating type (operating time 50 msec. or less).Fig. 1. Connection Diagram.Fig. 2. Automatic Closure.  Specifications T5000 Paralleling Relay        T       5       0       9       5   -       6       2       E Max. voltage  660V Voltage range  70 - 110% Consumption  2 x 5VA max. Frequency range  45 - 65Hz Voltage difference  10 - 15% Frequency difference  0.15 - 0.225Hz Combined setting Phase difference  6 - 9° Contact rating  AC: 400V, 5A, 1250VA DC: 150V, 5A, 120W Operating temperature  -20°C to +70°C Dielectric test  2500V, 50Hz EMC  CE according to EN50081-1, EN50082-1, EN50081-2, EN50082-2 Approvals  Certified by major marine classification societies Burn-in  50 hours before final test Enclosure material  Polycarbonate, flame retardant Weight  0.7kg Dimensions  70 x 100 x 115mm (H x W x D) Installation  35 DIN rail or two 4mm (3/16”) screws The specifications are subject to change without notice. Type Selection Table  TerminalsType 1-3 2-3 Function 5-7 6-7T5000.0010 450V 400VT5000.0020 230VT5000.0030 480V 415VT5000.0040 110V 100VT5000.0050 127V 120VT5000.0060 480V 415V Df = 9 - 13.5°, D F = 0.2 - 0.3HzT5000.0070 450V 400V D U = 15 - 20%, Df = 9 - 13.5°, D F = 0.2 - 0.3HzT5000.0080 110V 100V D U = 15 - 20%, Df = 9 - 13.5°, D F = 0.2 - 0.3HzT5000.0090 450V 400V Df = 9 - 13.5°, D F = 0.2 - 0.3HzT5000.0100 660VOther supply voltages and functions are available on request. Type Approvals The T5000 has been certified by the following classification societies:ã Bureau Veritas Certificateã Germanisher Lloyd Certificateã Polski Rejestr Staków Certificateã Romanian Register of Shipping Certificateã Russian Maritime Register of Shipping Main office:SELCO A/S Betonvej 10DK-4000 RoskildeDenmarkPhone: + 45 7026 1122Fax: + 45 7026 2522e-mail: selco.dk@selco.comwww.selco.com Fig. 3. Dimensions.             7             0  115             5              0  857.5              1             0  100 Fixing holes2 x ø 4.5 mmDimensions in mm Installation The two supplies should be connected to terminals 1-3 / 5-7 or 2-3 / 6-7 accor-ding to the voltage (see conn. diagram).Both supplies should remain disconnected until the function of the unit is needed, as shown in the connection diagram.An adjustment of D  voltage ±10% is normally recommended, but for small high speed engines a setting of up to ±15% can be used. The ±15% setting will give a faster synchronization than the ±10% setting.When commissioning, it is recommended to disconnect the closing signal (terminals   9 or 10). Check that the red LED “RELAY” indicates the closing signal, when the two systems (generator and  busbar) are in phase accordance. If this happens in 180° phase displace-ment, the wires to terminals 1 or 2 and 3 must be interchanged.
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks