Digital Tapchanger Control M-2001C CONTROLS ã LTC transformer, substation regulator, and line regulator control provides reliable operation with expanded capabilities ã Available in four models; Comprehensive, Base-T, Base-RS and Base-R ã Adapter panels to retroft popular industry tapchanger controls ã Ten on-board communication protocols ã Count Window - Works even with noisy operation counter contacts ã Field-updatable programming ã Reverse power detection/oper
Transcript
  Digital Tapchanger Control M-2001C CONTROLS  ã LTC transformer, substation regulator, and line regulator control provides reliable operation with expanded capabilities ã Available in four models; Comprehensive, Base-T, Base-RS and Base-R ã Adapter panels to retrot popular industry tapchanger controls ã Ten on-board communication protocols ã Count Window - Works even with noisy operation counter contacts ã Field-updatable programming ã Reverse power detection/operation ã Demand metering/Data Logging with Date/Time Stamp ã Entire control conguration prints out from TapTalk ®  ã SCAMP TM  (SCADA Controllable Auto/ Manual Pushbutton) Adapter Panel Auto/Manual Switch State can be changed by a SCADA command pushbutton ã Overcurrent protection ã SCADA HeartBeat ã Manual HeartBeat Timer ã LDC with R & X or Z-compensation Digital Tapchanger Control for Transformers and Regulators Comprehensive Model Shown  ã Increased Bandwidth to 10 Volts ã Ethernet port optional ã Supports terminal mode for modem communications in TapTalk ã Transformer paralleling by circulating current, external master-follower circuitry, or ∆ VA R ®  methods ã Standard LCD display (rated –20 to +70 degrees Celsius.) Vacuum Fluorescent display optionally available (rated –40 to +80 degrees Celsius) ã Optional Control Power Backup Input for Fiber Optic loop-through communication ã M-2829 TapPlot ®  for Windows TM  Analysis Software allows the plotting, printing and analysis of Tap Information   –2– M-2001C Digital Tapchanger Control Comprehensive Version Features The Comprehensive version includes all M-2001C features and can be used for LTCs or regulators where SCADA communications are desired.  ã Adjustable Bandcenter ã Adjustable Bandwidth ã Line Drop Compensation, R and X Compensation ã Time Delay, Denite and Inverse ã InterTap Time Delay ã Selectable Outputs, Continuous or Pulsed ã Reverse Power Operation, for Transformer LTC and Single-Phase Regulator applications ã CT to VT Phasing Correction ã Real-Time Metering of measured and calculated parameters  ã Demand Metering with selectable time interval ã Drag Hands Operation ã Adjustable Line Overcurrent Tapchange Inhibit ã Voltage Limits ã Tap Position Limits ã Runback ã Three independent Voltage Reduction Steps ã Sequential and Non-Sequential Operation ã SCADA HeartBeat ã Manual HeartBeat Timer ã VT R atio Correction  ã Self-Test Alarm Output Contacts ã User Programmable Alarm Contacts ã Operations Counter ã Resettable Operations Counter ã Harmonic Analysis through TapTalk  ®   ã Tap Position Record ã Auto/Off/Manual Switch Status ã A or B Regulator Type Selection ã Alarm Contact Outputs (2) ã Control Voltage Input ã Motor Power Input ã Line Current Input ã Raise Output ã Lower Output ã 20 Character by 2 Row LCD Display ã Tap Position Knowledge by: – Contact KeepTrack™ – Shaft Coupled KeepTrack™ – Resistor Divider KeepTrack™ – Motor Direct Drive KeepTrack™ ã M-2029A TapTalk Communications Software ã M-2829 TapPlot  ®   Tap Analysis Software ã Adapter Panel Auto/Manual Switch Type Selection  ã Front RS-232 Communications Port COM2 ã External Inhibit of Auto Tapchange ã Circulating Current Paralleling Method ã Front Panel LEDs for Out-of-Band Raise , Out-of-Band Lower , Reverse Power Flow Rev Pwr   Detected, CPU OK , Line Drop Compensation LDC  In Effect, Voltage Reduction V/RED  in Effect, Auto Operation Block MANUAL , SCADA Control blocked LOCAL and Com1 TX  and RX .  ã Circulating Current Input ã Voltage Reduction 1 & 2 Inputs (Binary) (3 Steps Total) ã Neutral Position Detect (Binary) ã Counter Input (Binary) ã Seal-in/Switch Status Input (Binary) ã Non-Sequential/SCADA Block Input (Binary) ã Seal-in Output ã COM1 (top) RS-232, RS-485 and Fiber Optics ã Communication Protocols include BECO 2200, BECO 2179, Cooper 2179, Cooper 2179A, GP-2179, GP DNP3.0, DNP3.0, AL PWR DNP3.0, MISS PWR DNP3.0 and MODBUS. Comprehensive Optional Features  ã Paralleling ∆ VAR  ®   Methods  ã Vacuum Fluorescent Display (rated –40 to +80 degrees Celsius.) ã Ethernet Port COM3 (10 Mpbs) is available through an RJ-45 jack on the top of the control. This port supports DNP over TCP/IP, BECO 2200 over TCP/IP, MODBUS over TCP/IP, and IEC 61850/UCA 2.0 over TCP/IP. ã Control Power Back-Up Input – input (+12 V dc) for backup of Fiber Optic loop-through communication Comprehensive Accessories  ã M-2025B(D) Current Loop Interface Module-Current-To-Voltage analog converter for tap position sensors  ã M-2026 AC-DC Control Power Backup Supply ã M-2027 Control Power Backup Supply - AC Only ã M-2948 Tap Position Sensor   –3– M-2001C Digital Tapchanger Control Base-T Version Features The Base-T version of the M-2001C is designed for transformers. It uses one COMM port (Com2) for communications.  ã Adjustable Bandcenter ã Adjustable Bandwidth ã Line Drop Compensation, R and X Compensation ã Time Delay, Denite and Inverse ã InterTap Time Delay ã Selectable Outputs, Continuous or Pulsed ã Reverse Power Operation, for Transformer LTC and Single-Phase Regulator applications ã CT to VT Phasing Correction ã Real-Time Metering of measured and calculated parameters  ã Demand Metering with selectable time interval ã Drag Hands Operation ã Adjustable Line Overcurrent Tapchange Inhibit ã Voltage Limits ã Tap Position Limits ã Runback ã Three independent Voltage Reduction Steps ã Sequential and Non-Sequential Operation ã VT R atio Correction  ã Self-Test Alarm Output Contacts ã User Programmable Alarm Contacts ã Operations Counter ã Resettable Operations Counter ã Harmonic Analysis through TapTalk  ®   ã Tap Position Record ã Auto/Off/Manual Switch Status ã A or B Regulator Type Selection ã Alarm Contact Outputs (2) ã Control Voltage Input ã Motor Power Input ã Line Current Input ã Raise Output ã Lower Output ã Tap Position Knowledge by: – Contact KeepTrack™ – Shaft Coupled KeepTrack™ – Resistor Divider KeepTrack™ – Motor Direct Drive KeepTrack™ ã 20 Character by 2 Row LCD Display ã M-2029A TapTalk Communications Software ã M-2829 TapPlot  ®   Tap Analysis Software ã Front Panel LEDs for Out-of-Band Raise , Out-of-Band Lower , Reverse Power Flow Rev Pwr  Detected, CPU OK , Line Drop Compensation LDC  In Effect, Voltage Reduction V/RED  in Effect and Auto Operation block MANUAL ( LOCAL and Com1 TX  and RX LEDs are NOT functional on BASE-T Versions). ã Includes BECO 2200 protocol on COM2 port ã Circulating Current Paralleling Method ã Front RS-232 Communications Port COM2 ã External inhibit of Auto Tapchange (non-sequential) ã Circulating Current Input ã Voltage Reduction 1 & 2 Inputs (Binary) (3 Steps Total) ã Neutral Position Detect (Binary) ã Counter Input (Binary) ã Seal-in/Switch Status Input (Binary) ã Non-sequential/SCADA Block Input (Binary) ã Seal-in Output Base-T Optional Features  ã Vacuum Fluorescent Display (rated –40 to +80 degrees Celsius.) ã ∆ VAR  ®   Paralleling Methods ã Control Power Back-Up Input – input (+12 V dc) for backup of Fiber Optic loop-through communication Base-T Accessories  ã M-2025B(D) Current Loop Interface Module-Current-To-Voltage analog converter for tap position sensors  ã M-2026 AC-DC Control Power Backup Supply ã M-2027 Control Power Backup Supply - AC Only ã M-2948 Tap Position Sensor   –4– M-2001C Digital Tapchanger Control Base-RS Version Features The Base-RS version of the M-2001C is designed pri - marily for regulators, but can also be applied to LTCs where SCADA communication is required. It provides one SCADA COMM port (COM1) as either an optional RS-485 or ber optics port for communications. ã Adjustable Bandcenter ã Adjustable Bandwidth ã Line Drop Compensation, R and X Compensation ã Time Delay, Denite and Inverse ã InterTap Time Delay ã Selectable Outputs, Continuous or Pulsed ã Reverse Power Operation, for Transformer LTC and Single-Phase Regulator applications ã CT to VT Phasing Correction ã Real-Time Metering of measured and calculated parameters  ã Demand Metering with selectable time interval ã Drag Hands Operation ã Adjustable Line Overcurrent Tapchange Inhibit ã Voltage Limits ã Tap Position Limits ã Runback ã Self-Test Alarm Output Contacts ã Three independent Voltage Reduction Steps ã Sequential and Non-Sequential Operation ã SCADA HeartBeat ã Manual HeartBeat Timer ã VT R atio Correction  ã Tap Position Knowledge by Motor Direct Drive KeepTrack™ method ã Operations Counter ã Resettable Operations Counter ã Harmonic Analysis through TapTalk  ®   ã Tap Position Record ã Auto/Off/Manual Switch Status ã A or B Regulator Type Selection ã Control Voltage Input ã Motor Power Input ã Line Current Input ã Raise Output ã Lower Output ã 20 Character by 2 Row LCD Display ã M-2029A TapTalk Communications Software ã M-2829 TapPlot  ®   Tap Analysis Software ã Adapter Panel Auto/Manual Switch Type Selection ã Front Panel LEDs for Out-of-Band Raise , Out-of-Band Lower , Reverse Power Flow Rev Pwr  Detected, CPU OK , Line Drop Compensation LDC  In Effect, Voltage Reduction V/RED  in Effect, Auto Operation Block MANUAL , SCADA Control blocked LOCAL and Com1 TX  and RX .  ã Includes BECO 2200 protocol on COM2 port ã Front RS-232 Communications Port COM2 ã Voltage Reduction 1 & 2 Inputs (Binary) (3 Steps Total) ã Non-Sequential/SCADA Block Input (Binary) ã Neutral Position Detect (Binary) ã Counter Input (Binary) ã Seal-in/Switch Status Input (Binary) ã Seal-in Output ã Communication Protocols include BECO 2200, BECO 2179, Cooper 2179, Cooper 2179A, GP-2179, GP DNP3.0, DNP3.0, AL PWR DNP3.0, MISS PWR DNP3.0 and MODBUS. Base-RS Optional Features  ã Vacuum Fluorescent Display (rated –40 to +80 degrees Celsius.) ã Control Power Back-Up Input – input (+12 V dc) for backup of Fiber Optic loop-through communication  ã COM1 (top) RS-485 or Fiber Optics Base-RS Accessories  ã M-2026 AC-DC Control Power Backup Supply ã M-2027 Control Power Backup Supply - AC Only

KPandey.pdf

Jul 23, 2017

Grinding Stress 1

Jul 23, 2017
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks