Documents

MB-FB-2R 185085

Categories
Published
of 4
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Description
fieldbus
Transcript
     R   e   l   e   a   s   e   d   a   t   e   2   0   1   4  -   0   7  -   2   5   1   1   :   0   0   D   a   t   e   o   f   i   s   s   u   e   2   0   1   4  -   0   7  -   2   5   1   8   5   0   8   5_   e   n   g .   x   m   l MB-FB-2R 1 Refer to General Notes Relating to Pepperl+Fuchs Product Information .Pepperl+Fuchs GroupUSA: +1 330 486 0002Singapore: +65 6779 9091Germany: +49 621 776 2222www.pepperl-fuchs.compa-info@us.pepperl-fuchs.compa-info@de.pepperl-fuchs.compa-info@sg.pepperl-fuchs.com Universal Fieldbus Power Hub, Motherboard, Common Interface Bulk 2Bulk 1 -+-+-+ S - S +-+ S +-  SS -+ HostTrunk + - Bulk 1Bulk 2 Z CREST T Host 2Trunk 2 + - Host 1Trunk 1Diagnostic Bus +- Alarm ConnectionAssembly ã2 segments, redundant, individual modules per segmentãSupports all PLC and DCS hostsãHigh-Power Trunk: Live work on devices in any hazardous areaãFeatures for best signal quality, low heat dissipationãFor FOUNDATION Fieldbus H1 and PROFIBUS PAãOptional Advanced DiagnosticsãPassive impedance and CREST technology for high reliabilityãSupports Ex ic/nL voltage limitationãInstallation in Zone 2/Div. 2 Function The FieldConnex ® Universal Power Hub is a modular fieldbus power supply, providing the most options for most reliable communication. It supports explosion protection e.g. the High-Power Trunk for longest cable run and highest device count. The Power Hub supports optional Advanced Diagnostics for fast fieldbus commissioning and online monitoring.The motherboard is the wiring interface and mounting plate with common screw terminals for all DCS and PLC host systems. Sockets for all modules enable simple installation and replacement without tools. Certain motherboards enable power redundancy with seamless transfer. Pairs of modules feed each segment.Availability and a long service life are achieved through: only one passive impedance filter per segment with CREST for superior signal transmission, optimized design for low power dissipation and high-availability fieldbus termination. Any mounting direction allows optimized and space-saving cabinet layout. Features R ®     R   e   l   e   a   s   e   d   a   t   e   2   0   1   4  -   0   7  -   2   5   1   1   :   0   0   D   a   t   e   o   f   i   s   s   u   e   2   0   1   4  -   0   7  -   2   5   1   8   5   0   8   5_   e   n   g .   x   m   l Technical dataMB-FB-2R 2 Refer to General Notes Relating to Pepperl+Fuchs Product Information .Pepperl+Fuchs GroupUSA: +1 330 486 0002Singapore: +65 6779 9091Germany: +49 621 776 2222www.pepperl-fuchs.compa-info@us.pepperl-fuchs.compa-info@de.pepperl-fuchs.compa-info@sg.pepperl-fuchs.com Supply Connection redundantRated voltage 19.2 ... 35 V SELV/PELVRated current 16 A Fieldbus interface Number of segments Redundant 2Host-side redundant general purpose hostTerminating resistor selectable 100 Ω Indicators/operating means Fault signal VFC alarm output via connectors Electrical isolation Fieldbus segment/Fieldbus segment functional insulation acc. to DIN EN 50178, rated insulation voltage 50 V eff Fieldbus segment/Supply functional insulation acc. to DIN EN 50178, rated insulation voltage 50 V eff Directive conformity Electromagnetic compatibility Directive 2004/108/EC EN 61326-1:2013 Standard conformity Electromagnetic compatibility NE 21:2011Degree of protection IEC 60529Fieldbus standard IEC 61158-2Shock resistance EN60068-2-27Vibration resistance EN60068-2-6Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Ambient conditions Ambient temperature -40 ... 60 °C (-40 ... 140 °F)Storage temperature -40 ... 85 °C (-40 ... 185 °F)Relative humidity < 95 % non-condensingShock resistance 15 g , 11 msVibration resistance 1 g , 10 ... 150 HzPollution Degree max. 2, according to IEC 60664Corrosion resistance acc. to ISA-S71.04-1985, severity level G3 Mechanical specifications Connection type screw terminalsCore cross-section 2.5 mm 2 Housing material PolycarbonateHousing width 125 mmHousing height 220 mmHousing depth 65 mmDegree of protection IP20Mass approx. 500 gMounting DIN mounting railCoating conformal coated Data for application in connection with Ex-areas Statement of conformity TÜV 04 ATEX 2500 XGroup, category, type of protection, temperature class ¬  II 3 G Ex nA IIC T4 GcDirective conformity Directive 94/9/EC EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 International approvals FM approval CoC 3024816, CoC 3024816CApproved for Class I, Division 2, Groups A, B, C, D, T4 / Class I, Zone 2, AEx/Ex nA IIC T4IECEx approval IECEx TUN 13.0038XApproved for Ex nA IIC T4 Gc Certificates and approvals Marine approval DNV A-10798 General information Supplementary information Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.     R   e   l   e   a   s   e   d   a   t   e   2   0   1   4  -   0   7  -   2   5   1   1   :   0   0   D   a   t   e   o   f   i   s   s   u   e   2   0   1   4  -   0   7  -   2   5   1   8   5   0   8   5_   e   n   g .   x   m   l Technical dataMB-FB-2R 3 Refer to General Notes Relating to Pepperl+Fuchs Product Information .Pepperl+Fuchs GroupUSA: +1 330 486 0002Singapore: +65 6779 9091Germany: +49 621 776 2222www.pepperl-fuchs.compa-info@us.pepperl-fuchs.compa-info@de.pepperl-fuchs.compa-info@sg.pepperl-fuchs.com Description:1Power Supply Modules, see separate data sheets2Diagnostic Module, see separate data sheet3Connections for fieldbus trunk, terminator switch4Screening/earthing kit for trunk cables shield, optional accessory5Mounting slot for DIN rail6Motherboard MB-FB-2R7Connections for alarm voltage free contact and diagnostics busDiagnostics link cable, optional accessory8Connections for redundant host with host link switch9Connections for redundant bulk power supply Dimensions         1        2       5        2       7       5        0 3616         3       5        1        6        2        8 110220246 +- S   S E  G1  +- S   S E  G2 P R I  P WR  S E  C P WR   S  -+  S E  G1   O F  F   O N  H  o  s  t  A H  o  s  t  B   S  -+ S  -+  S E  G2   O F  F   O N  H  o  s  t  A H  o  s  t  B   S  -+ 123465789     R   e   l   e   a   s   e   d   a   t   e   2   0   1   4  -   0   7  -   2   5   1   1   :   0   0   D   a   t   e   o   f   i   s   s   u   e   2   0   1   4  -   0   7  -   2   5   1   8   5   0   8   5_   e   n   g .   x   m   l Technical dataMB-FB-2R 4 Refer to General Notes Relating to Pepperl+Fuchs Product Information .Pepperl+Fuchs GroupUSA: +1 330 486 0002Singapore: +65 6779 9091Germany: +49 621 776 2222www.pepperl-fuchs.compa-info@us.pepperl-fuchs.compa-info@de.pepperl-fuchs.compa-info@sg.pepperl-fuchs.com 1  follows bulk power supplyThe following diagnostic modules are compatible with this motherboard.The stationary and mobile Advanced Diagnostic Module (ADM) and related components provide measurement tools for the fieldbus physical layer. The ADM monitors many quality indicating values of the fieldbus physical layer. An expert system, which is included, analyzes the values and issues easy to understand messages indicating cause and remedy. The ADM is recommended for:- Faster commissioning and plant start-up:  Installation issues are known and corrected before loop check commences- Reliable operation through online monitoring : The quality of the physical layer and installation is monitored making fieldbus a manageable asset - Efficient troubleshooting:  An expert system guides the user through issues and faults in the fieldbus installationMany other tools are included that enhance fieldbus installation and upkeep. Please see datasheet on HD2-DM-A.see manual HD2-FBPS-1.17.500HD2-FBPS-1.23.500HD2-FBPS-1.25.360HD2-FBPS-1.500HD2-FBCL-1.500Power Output Voltage (V)15 ... 1721 ... 2325 ... 2828 ... 30- 1 Current (mA)500500360500500Limit U 0  (V)17.524--- Device in ...Type of ProtectionRequired Installation Components Zone 0/Div. 1Intrinsically safe Ex ia     FieldBarrierZone 1/Div. 1Intrinsically safe Ex ia     FieldBarrierZone 1/Div. 1Flameproof Ex d     Segment Protector R-SP-E12 or any Segment Protector installed in Zone2Zone 2Intrinsically safe Ex ic (FISCO)   Selected Segment ProtectorsZone 2Intrinsically safe Ex ic (Entity)   Selected Segment ProtectorsDiv. 2Non-incendive      Any Segment Protector; power module selection depends on voltage of field deviceSafe AreaNo specific type of protection     Segment Protector recommended Type codeDescription HD2-DM-BDiagnostic Module, basic versionHD2-DM-ADiagnostic Module, advanced versionHD2-DM-A.RODiagnostic Module, advanced version, relay output Type codeDescription ACC-MB-HSKScreening/earthing kitACC-MB-HDCDiagnostic link cable, length 6 cmACC-MB-CCSet of two connector covers for Ex ic hazardous area applications   Compatible power modulesDiagnostic module selectionAccessoriesInstallation note
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks