Documents

r Pds Eng Ps-00363 h Web

Categories
Published
of 24
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Related Documents
Share
Description
Coriolis Merila protoka
Transcript
  Micro Motion  ®   R-Series Coriolis meters are simple and reliable, and feature a compact form factor that is easy to install and maintain. Versatile R-Series meters are used in a wide range of industries to obtain the fundamental benefits of Coriolis flow measurement. Simple to install and easy to use Coriolis flow measurement ãMeasure flow in either mass or   volume units for any applicationãInstall easily anywhere with compact design that is immune to flowprofile effectsãKeep process loops easy to clean and maintain with self-drainingdesign Broad range of application coverage ã316L stainless steel construction for compatibility with most fluids Superior reliability ãNo moving parts to wear or replace minimizes maintenance for long-term reliability Peak performance Coriolis meter General purpose flow-only Coriolis meter Hygienic compact drainable Coriolis meterStraight tube full-boreCoriolis meter High performance compact drainable Coriolis meter ELITE ® R-Series H-SeriesT-SeriesF-Series Product Data Sheet   PS-00363, Rev. H April  201 3 Extreme low-flow Coriolis meter LF-Series Micro Motion ®  R-Series Coriolis Flow Meters Peak performance high capacity meter ELITE HC  2 Micro Motion  ®   R-Series Coriolis Flow Meters Micro Motion R-Series Coriolis Flow Meters Micro Motion Coriolis meters meet a vast range of application needs, ranging from extreme low-flow up to high-flow, high-capacity lines. Cryogenic, hygienic, high-temperature, and high-pressure—Micro Motion meters can handle them all. Micro Motion meters are available with a variety of wetted parts to ensure the best material compatibility. Coriolis meters. Coriolis meters offer dramatic benefits over traditional volumetric measurement technologies. Coriolis meters:ãDeliver accurate and repeatable process data over a wide range of flow rates and process conditions.ãProvide direct inline measurement of mass flow and density, and also measure volume flow and temperature—all from a single device.ãHave no moving parts, so maintenance costs are minimal.ãHave no requirements for flow conditioning or straight pipe runs, so installation is simplified and less expensive.ãProvide advanced diagnostic tools for both the meter and the process. R-Series Coriolis flow meters. Micro Motion R-Series Coriolis meters are designed to handle most common mass and volume flow measurement applications. The compact case of the R-Series meter allows it to fit almost anywhere, and integral electronics make installation and setup easy.R-Series meters support a number of digital communication protocols, such as HART  ®  , Modbus  ®  , F OUNDATION  fieldbus ™ , and PROFIBUS-PA. Contents Liquid flow performance . . . . . . . . . . . . . . . . . . . . 3Gas flow performance. . . . . . . . . . . . . . . . . . . . . . 5Temperature specifications . . . . . . . . . . . . . . . . . . 7Pressure ratings . . . . . . . . . . . . . . . . . . . . . . . . . . 9Vibration limits. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Environmental effects . . . . . . . . . . . . . . . . . . . . . . 8Hazardous area classifications. . . . . . . . . . . . . . .12Materials of construction. . . . . . . . . . . . . . . . . . . .14Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Fitting options. . . . . . . . . . . . . . . . . . . . . . . . . . . .18Ordering information. . . . . . . . . . . . . . . . . . . . . . .21  Micro Motion  ®   R-Series Coriolis Flow Meters 3 Liquid flow performance MassVolume (1) (1)Volumetric measurement is based on a process-fluid density of 1g/cm  3   (1000kg/m  3   ). For fluids with density other than 1g/cm  3   (1000kg/m  3   ), the volume flow rate equals the maximum mass flow rate divided by the fluid’s density. lb/minkg/hgal/minl/h Maximum flow rate R025S, R025P1002720122720R050S3008160368160R100S120032,65014432,650R200S320087,10038487,100 Mass flow accuracy (2) (2)Stated flow accuracy includes the combined effects of repeatability, linearity, and hysteresis. All specifications for liquids are based on reference conditions of water at 68 to 77 °F (20 to 25 °C) and 15 to 30 psig (1 to 2 bar), unless otherwise noted. ±0.5% of rate (3) Volume flow accuracy ±0.5% of rate (3) Mass and volume flow repeatability ±0.25% of rate (3) (3)When flow rate < (zero stability/0.005), then accuracy = ±[(zero stability/flow rate) × 100]% of rate and repeatability = ±[½(zero stability/flow rate) × 100]% of rate. lb/minkg/hgal/minl/h Zero stability R025, R025P0.010.270.00120.27R050S0.030.820.00360.82R100S0.123.270.01443.27R200S0.328.710.03848.71  4 Micro Motion  ®   R-Series Coriolis Flow Meters Liquid flow performance continued  Typical accuracy, turndown, and pressure drop with transmitter with MVD Technology Pressure drop is dependent on process conditions. To determine accuracy, turndown, and pressure drop with your process variables, use Micro Motion’s product selector, available at www.micromotion.com. Turndown from maximum flow rate20:110:11:1 Accuracy, ± %0.500.500.50Pressure drop psi  0.10.81354 bar  0.0070.053.4 2.52.01.51.00.50 –0.5 –1.0 –1.5 –2.0 –2.51009080706050403020100 20:110:11:1    A  c  c  u  r  a  c  y ,   % Flow rate, % of maximum
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks