Toshiba Inventor VFD AS1 Manual
Transcript
  E6581301  Instruction Manual T he   new   high - performance   inverter    TOSVERT TM   VF- AS1 200V class 0.4  75kW400V class 0.75  500kW R ead   first  II  I I ntroduction I   S afety   precautions C ontents 2 C onnection   equipment   3 O perations 4 S earching   and   setting   parameters 5 B asic   parameters 6 E xtended   parameters 7 O peration   with   external   signal 8 M onitoring   the   operation   status 9 T aking   measures   to   satisfy   the  CE/UL/CSA standards 10   S election   of peripheraldevices   11   T able   of    parameters   12 2 S pecifications   13 3 Before making a service call   14 4 I nspection   and   maintenance   15 5 W arranty   16  6 D isposal   of    the   inverter  NOTICE1.Make sure that this instruction manual is delivered to the end user of the inverter unit.2.Read this manual before installing or operating the inverter unit, and store it in a safe place for reference.  E6581358 ③   Errata sheet This errata sheet provides updated information on VF-AS1 Instruction Manual E6581301   . No.PageChange fromChange to1A-4VFAS1-2055PL, 4055PL, and 4075PL main circuitterminal boardR/L1~W/T3 terminal = M5 screwVFAS1-2055PL, 4055PL, and 4075PL main circuitterminal boardR/L1~W/T3 terminal = M4 screw(It is due to change into M5 screw.)2E-30Note 6: For the setting  =   or   to takeeffect, power needs to be turned off and then turnedback on.Note 6: For the setting  =   or  to takeeffect, power needs to be turned off and then turnedback on. And this parameter is invalidated for theratings of 90 kW and over.3E-40Minimum allowable resistance400V Class 132kW=2.5 Ω 400V Class 160kW=1.3 Ω Minimum allowable resistance400V Class 132kW=1.9 Ω 400V Class 160kW=1.9 Ω 4F-29   :Horizontal operation (counter weight)   :Horizontal operation5J-7DC reactor VFAS1-2055PL= -VFAS1-2075PL= -DC reactor VFAS1-2055PL=DCL-2055VFAS1-2075PL=DCL-21106J-7High attenuation type radio noise reduction filter  VFAS1-4550PL, 4750PL=NF3150C-MJHigh attenuation type radio noise reduction filter  VFAS1-4550PL, 4750PL=A filter is built into each of these inverters.7K-133:Horizontal operation (counter weight)3:Horizontal operation8K-17    Speed control= ●●    Speed control= ● 9K-42Positive logic 112/Negative logic 113 =Control switching (torque/position)Positive logic 112/Negative logic 113 =Speed/Torque switching10L-1VFAS1-2185PM~2450PM protective method=IP20 Enclosed type (JEM1030)VFAS1-2185PM~2450PM protective method=IP00 Open type (JEM1030)11L-1VFAS1-4220PL~4750PL protective method=IP20 Enclosed type (JEM1030)VFAS1-4220PL~4750PL protective method=IP00 Open type (JEM1030)12L-2VFAS1-2750P voltage-frequency=Three-phase 200~240V-50/60Hz Note 5VFAS1-2750P voltage-frequency=Three-phase 200~220V-50Hz Note 5Three-phase 200~240V-60Hz Note 513. Addition to Danger (page A-13) ã@ã@Danger  ProhibitedIn case of one phase grounding system, do not change the connection of grounding capacitor before factory setting. If connection changed (this means the capacitance is increased), thecapacitor may become damaged.14. Addition to Note (page F-30)   Learning function When   set   and   is set  , please set the direction of running to forward. When   set   and  is set  , please set the direction of running to reverse.15. Addition to Note (page F-61) Note2:When power on or reset operation, the power supply voltage is detected. If the setting value of parameter  is too low, the setting value is automatically adjusted to stabilize the performance.   E6581358‡D 1  E6581357② 16.   Change to  wire size (page J-1) Main circuit wire sizeInverter model AWGmm 2 VFAS1-4200KPC/4220KPC400MCMã@ã¨ã@300MCM × 2200ã@ã¨ã@150 × 2Wire size for connecting a DC reactor Inverter model AWGmm 2 VFAS1-4132KPC/4160KPC-150ã@ã¨ã@100 × 2VFAS1-4200KPC/4220KPC300MCM × 2ã@ã¨ã@300MCM × 3150 × 2ã@ã¨ã@150 × 3VFAS1-4280KPC400MCM × 2ã@ã¨ã@300MCM × 4200 × 2ã@ã¨ã@150 × 417. Change to  magnetic contactor (page J-2) Inverter modelMagnetic contactor (Without Reactor)VFAS1-2037PLLC1D126ã@ã¨ã@LC1D186VFAS1-2055PLLC1D126ã@ã¨ã@LC1D256Inverter modelMagnetic contactor (With Reactor)VFAS1-4075PLLC1D186ã@ã¨ã@LC1D126   E6581358‡D 2  E65813011  I  I. Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely prevent injury to yourself and other people around you as well as prevent damage to property in the area.Thoroughly familiarize yourself with the symbols and indications shown below and then continue to read the manual.Make sure that you observe all warnings given. Explanation of markings MarkingMeaning of markingDangerIndicates that errors in operation may lead to death or serious injury. WarningIndicates that errors in operation may lead to injury (*1) to people or that theseerrors may cause damage to physical property. (*2) (*1) Such things as injury, burns or shock that will not require hospitalization or long periods of outpatient treatment.(*2) Physical property damage refers to wide-ranging damage to assets and materials. Meanings of symbols MarkingMeaning of markingIndicates prohibition (Don't do it).What is prohibited will be described in or near the symbol in either text or pictureform.Indicates something mandatory (must be done).What is mandatory will be described in or near the symbol in either text or pictureform.Indicates danger.What is dangerous will be described in or near the symbol in either text or pictureform.Indicates warning.What the warning should be applied to will be described in or near the symbol ineither text or picture form.   Limits in purpose This inverter is used for controlling speeds of three-phase induction motors in general industrial use.   Safety precautions ▼ The inverter cannot be used in any device that would present danger to the humanbody or which a malfunction or error in operation would present a direct threat tohuman life (nuclear power control device, aviation and space flight control device,traffic device, life support or operation system, safety device, etc.). If the inverter isto be used for any special purpose, first get in touch with the supplier. ▼ When using inverters for critical equipment, even though the inverters aremanufactured under strict quality control always fit your equipment with safetydevices to prevent serious accident or loss should the inverter fail (such as failureto issue an inverter trouble signal) ▼ Do not use the inverter for loads other than those of properly applied three-phaseinduction motors in general industrial use.(Use in other than properly applied three-phase induction motors may cause anaccident.)When the inverter is used to control the operation of a permanent magnet motor, acombination test must be conducted in advance. For details on the test, contactyour supplier.
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks