Watlow® believes that UL® and CSA recognition information is necessary to confirm the reliability of our heating products in relationship to your application. As such, the accompanying Agency Recognition charts illustrate the extent of coverage each heater type provides. Specific end use application information is required for each agency marking. Some products carry U.S. and Canada approvals.
Transcript
  563  WATLOW  ®  Agency Certifications, Recognition and Approvals  WATROD and FIREBAR ®  Element and Assemblies  Agency Recognition UL ®  and CSA recognition information charts are provided to ensure:ã Safety parameters in relationship to stated voltage and amperageã Approved sheath materials, end seals and assembly electrical enclosuresWatlow believes that UL ®  and CSA recognition information is necessary to confirm the reliability of our heating products in relationship to your application. As such, the accompanying  Agency Recognition  charts illustrate the extent of coverage each heater type provides. Specific end use application information is required for each agency marking. Some products carry U.S. and Canada approvals. ® ® UL ®  Recognition and Listing File Number E52951 (UL ®  499) — Component Recognition  All information for UL ®  File #E52951 can be found in the UL ®  Directory, Volume 2 under “Heaters Miscellaneous” (Classification KSOT2). Elements (Volume 2, Section 1)   a 45 in water applications only. Note:  All end seal types apply to all diameter heaters. 2 Maximum sheath temperatures apply, contact your Watlow representative 3 U6M2 series up to 250V Note:  All end seal types apply to all diameter heaters 0.210 (6.0) RK   series  U0-xx  250 15 N/A N/A 1  /  16   (1.6) Nickel alloy 400, Epoxy resin, 0.260 (6.6) RA   series U1-xx  250 15 N/A N/A 1  /  16  (1.6) 600, 800, 840, Lavacone, 0.315 (8.0) RB  series U3-xx  480 30 N/A N/A 1  /  16  (1.6) 800H, Silicone resin, 0.375 (9.5) RD , RS  series U5-xx  480 30 N/A N/A 3  /  16  (4.8) 304, 316 SS, Silicone rubber, 0.430 (10.9) RC  series U6-xx  600 40 a  N/A N/A 5  /  32  (4.0) Steel, Titanium, ULTRAGARD, 0.475 (12.0) RG  series U7-xx  600 40 N/A N/A 3  /  16  (4.8) Copper coated SF-99, 0.490 (12.4) RJ  series U8-xx  600 40 N/A N/A 3  /  16  (4.8) steel Ceramic potting  Hastelloy C22, C276   WATROD Allowable Max. Watt Min. Bend Allowable End Diameter Part Max. Max. Density Radius Sheath Seal in. (mm) Numbers Volts Amps W/in 2  W/cm 2  in. (mm) Materials Types  0.430 (10.9) U6M  series 480 3   N/A N/A N/A 1  /  2   (13.0) Nickel alloy 800,   Epoxy resin, 0.475 (12.0) U7M  series 480 N/A  N/A N/A 5  /  8  (15.9) 840, Silicone resin, 0.490 (12.4) U8M  series 480 N/A  N/A N/A 5  /  8  (15.9) 304, 316 SS, Silicone rubber, Steel, Titanium Lavacone, SF-99, Ceramic potting  MULTICOIL Allowable Max. Watt Min. Bend Allowable End Diameter Part Max. Max. Density  2  Radius Sheath Seal in. (mm) Numbers Volts Amps W/in 2  W/cm 2  in. (mm) Materials Types Elements (Volume 2, Section 6)   Screw Plug All catalog models B  General purpose or moisture resistant with or without thermostat Series U1  to U9 (Type “3”   thermostat excluded) Flange All catalog models FE , FG , FH , FK  , FL , FM , FN , FO , FP  General purpose or moisture resistant with or without thermostat  FR , FS , FT , FW —Series U1  to U9 (Type “3” thermostat excluded)   Circulation All catalog models CB , CF , CP  General purpose or moisture resistant with or without thermostat Series U1  to U9 (Type “3” thermostat excluded)   Over-the-Side All catalog models OL , OR  and  VL  Moisture resistant with or without thermostat Series U1  to U9 , except U2  and U4  Duct All catalog models D6  to D125 , MDH6  to MDH60 , General purpose enclosure only LDH9  to LDH225  Series U1  to U9  and U0, UE    Air or Immersion Heating 5  /  8  (15.9) FA, FS  series  A-xx  480 N/A 50 (5.1) 1 (25) 1  /  2  (13) 3  Nickel alloy 800, Epoxy resin, 1 (25.0) FB, FS  series 480 N/A 50 (5.1) 1 (25) 1  /  2  (13) 3  840, Lavacone, 304 SS Silicone resin, Silicone rubber, SF-99, Ceramic potting Liquid Immersion Heating Only 5  /  8  (16) FA, FS  series U-xx  480 N/A 160 (24.7) 1 (25) 1  /  16  (1.6) Nickel alloy 800, Epoxy resin, 1 (25) FB, FS  series 480 N/A 160 (24.7) 1 (25) 1  /  16  (1.6) 840, Lavacone, 304 SS Silicone resin, Silicone rubber, SF-99, Ceramic potting 564  WATLOW  ®  Agency Certifications, Recognition and Approvals  WATROD and FIREBAR Element and Assemblies  Assemblies Refer to applicable WATROD and FIREBAR elements for maximum voltage, watt density and sheath materials.  Heater Type Allowable Part Numbers Electrical Enclosure Options FIREBAR Allowable Max. Watt Min. Bend Radius Allowable End Height Part Max. Max . Density Major Axis Minor Axis  Sheath Seal in. (mm) Numbers Volts  Amps   W/in 2  (W/cm 2  )   in. (mm) in. (mm)  Materials TypesNotes:  UL ®  and CSA must be requested at the time the order is placed. All sheath materials and end seal types apply to all diameter heaters. 3 1 if >33 W/in 2 . UL ®  Recognition and Listing (Continued) Elements (Volume 2, Section 4)   Screw Plug Models T3 , T5 , T6 , T7 , T8 , T9  General purpose without thermostat Example: T336xxxx  Flange Models T3 , T5 , T6 , T7 , T8 , T9  General purpose without thermostat Example: T621xxxx 565  WATLOW  ®  Agency Certifications, Recognition and Approvals  WATROD and FIREBAR Element and Assemblies File Number E56488 (UL ®  1030)—Water Immersion Only (Classification UBJY2) — Component RecognitionElements  Heater Type Allowable Part Numbers Electrical Enclosure Options  0.315 (8.0) 480 7 18.5 (120) 1  /  8  (3.2) Nickel alloy 800, 840,  Epoxy, 0.375 (9.5) 480 7 18.5 (120) 1  /  8  (3.2) 304, 316 SS Silicone rubber,  0.430 (10.9) T  series 575 7 18.5 (120) 5  /  16  (7.9) Silicone resin 0.475 (12.0) Example:  T085CN3S  575 7 18.5 (120) 5  /  16  (7.9) 0.490 (12.4) 575 7 18.5 (120) 5  /  16  (7.9) 1 (25) T  series 250 N/A 80 (12.4) 1 (25) 5  /  32  (4) Nickel alloy 800 ,  Epoxy, Example: T085HN3W  304 SS Silicone rubber,  Silicone resin  WATROD Allowable Max. Max. Watt Min. Bend Allowable End Diameter Part Max. # of Density Radius Sheath Seal in. (mm) Numbers Volts Bends W/in 2  (W/cm 2  ) in. (mm) Materials Types  Assemblies Refer to applicable WATROD and FIREBAR elements for maximum voltage, watt density and sheath materials.  FIREBAR ®  Allowable Max. Max. Watt Min. Bend Allowable End Height Part Max. # of Density Major Axis Minor Axis  Sheath Seal in. (mm) Numbers Volts Bends W/in 2  (W/cm 2  ) in. (mm) in. (mm)  Materials TypesNote : UL ®  and CSA must be requested at the time the order is placed. File Number MH26554 (UL ®  574)—Electric Oil Heaters (Classification MDST2) — Component Recognition or Listing (Contact factory if UL ®  Listed marking is desired)Elements For reference only, marking applies only to assemblies noted below.  0.260 (6.6) Series 1-xx 250 15 23 (3.56) 1  /  16  (1.6) Steel, Epoxy resin, 0.315 (8.0) Series 3-xx 480 30 23 (3.56) 1  /  16  (1.6) Nickel alloy 400, Silicone resin, 0.375 (9.5) Series 5-xx 480 30 23 (3.56) 3  /  16  (4.8) 600, 800, 840, Silicone rubber, 0.430 (10.9) Series 6-xx 600 40 23 (3.56) 5  /  32  (4.0) 304, 316 SS, Lavacone 0.475 (12.0) Series 7-xx 600 40 23 (3.56) 3  /  16  (4.8) Titanium 0.490 (12.4) Series 8-xx 600 40 23 (3.56) 3  /  16  (4.8)   WATROD Allowable Max. Watt Min. Bend Allowable End Diameter Part Max. Max. Density Radius Sheath Seal in. (mm) Numbers Volts Amps W/in 2  (W/cm 2  ) in. (mm) Materials Types  Screw Plug Models BCS  and BGS  Enclosure Types 1 or 4, with or without thermostat. Series 1-xx  thru 9-xx , excluding series 2-xx  and 4-xx  Thermostat shall be Watlow Type 2, 2A, 4, 5A, 7A, 12, 12A  Assemblies Refer to applicable WATROD elements for maximum voltage, watt density and sheath materials.  Heater Type Allowable Part Numbers Electrical Enclosure OptionsNote:  All sheath materials and end seal types apply to all diameter heaters. Note:  All sheath materials and end seal types apply to all diameter heaters. Note:  UL ®  and CSA must be requested at the time the order is placed.  566  WATLOW  ®  Agency Certifications, Recognition and Approvals  WATROD and FIREBAR Element and Assemblies Declaration of Conformity  The Low Voltage Directive (LVD) (73/23/EEC) states that electrical and electronic equipment placed on the market in the European Union (EU) must be safe. The CE Marketing Directive (93/68/EEC) for the LVD came into force on January 1, 1995, subject to a two-year transition period. All heaters operating on a supply voltage of between 50 and 1000VAC and between 75 and 1500VDC fall within the scope of the LVD. The Self Declaration of Conformity shown on the right, backed by our risk assessment and technical file, assure that the product series shown on the Declaration meet the EU requirements. The declaration is not applicable to any of our heaters intended for use in an explosive atmosphere, or for radiological and medical purposes. For heaters intended for use in an explosive environment, see the  ATEX section  of page 568.

Guide to ethics

Jul 23, 2017
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks